Radiators up to 70 °C
The heating circuit runs on water from 20 to 70 °C, and the series reaches a maximum water temperature of 75 °C. A sound basis for radiators and renovation work.
Caldo Boost is an R290 heat pump for villas that heats system water up to 70 °C, a temperature suited to radiators and renovation projects. With a natural refrigerant, four models from 8 to 22 kW and operation down to −25 °C, it provides heating, cooling and domestic hot water with an SCOP of up to 4.69.

Home comfort with natural R290 refrigerant, Wi-Fi control and hot water up to 75°C.
The heating circuit runs on water from 20 to 70 °C, and the series reaches a maximum water temperature of 75 °C. A sound basis for radiators and renovation work.
R290 (propane) has a very low GWP. Because it is flammable (class A3), installation and servicing must be carried out by qualified technicians.
Under EN 14825, SCOP at 35 °C flow ranges from 4.60 to 4.69 (ηs up to 184.6%). At 55 °C flow it stays between 3.37 and 3.55.
Produces 159 to 377 litres of hot water per hour depending on the model, with Wi-Fi and IoT control. It uses a Highly compressor and a Shimge water pump.
Technical data are nominal values under standard test conditions. Actual performance may vary. Specifications may change without notice.
Swipe to explore all specifications.
| Model | 8 kW | 11 kW | 15 kW | 22 kW |
|---|---|---|---|---|
| Heating capacity (kW) · 30/35°C | 3.3~8.3 | 4.5~11.4 | 5.9~14.8 | 8.8~22.0 |
| Heating power input (kW) | 0.64~2.18 | 0.85~2.95 | 1.13~3.83 | 1.68~5.77 |
| COP | 3.81~5.17 | 3.86~5.29 | 3.86~5.22 | 3.81~5.24 |
| DHW capacity (kW) · 15/55°C | 3.7~7.4 | 5.2~10.2 | 6.6~13.2 | 7.8~17.6 |
| DHW COP | 3.52~4.69 | 3.55~4.71 | 3.54~4.67 | 3.51~4.66 |
| Heated water output (L/h) | 159 | 219 | 283 | 377 |
| Cooling capacity (kW) | 2.4~5.8 | 3.3~8.2 | 4.3~10.8 | 6.2~15.3 |
| EER | 2.65~3.04 | 2.67~3.06 | 2.71~3.10 | 2.73~3.12 |
| ηs / SCOP · 35°C outlet | 182.7% / 4.64 | 181.0% / 4.6 | 182.9% / 4.65 | 184.6% / 4.69 |
| ηs / SCOP · 55°C outlet | 136.0% / 3.48 | 137.0% / 3.5 | 131.9% / 3.37 | 138.9% / 3.55 |
| Noise dB(A) @1 m | 44 | 43 | 45 | 45 |
| Power supply | 230V/1Ph/50–60Hz | 230V/1Ph/50–60Hz | 230V/1Ph/50–60Hz | 380V/3Ph/50–60Hz |
| Max. power input (kW) | 3.1 | 4.1 | 5.2 | 7.6 |
| Max. current (A) | 14.2 | 18.8 | 23.8 | 14.3 |
| Water flow (m³/h) | 1.43 | 1.96 | 2.55 | 3.78 |
| Net weight (kg) | 112 | 120 | 138 | 170 |
| Unit dimensions (mm) | 1080×460×820 | 1080×460×960 | 1080×480×1060 | 1080×480×1372 |
| Refrigerant | R290/1.0kg | R290/0.95kg | R290/1.45kg | R290/1.4kg |
There are four models: 8, 11 and 15 kW on a 230 V single-phase supply, and 22 kW on a 380 V three-phase supply. Heating capacity at 30/35 °C runs from 3.3–8.3 kW on the smallest model to 8.8–22.0 kW on the largest, while hot water output rises from 159 to 377 litres per hour. With radiators, allow for a higher water temperature and an SCOP of 3.37–3.55 at 55 °C. Have a qualified installer confirm the final sizing.
See the full buying guideStraight answers on how heat pumps work, efficiency, installation and choosing a Caldorelli series.
Talk to a specialistYes, it is the series designed for that job: the heating circuit runs on water from 20 to 70 °C. Radiators typically work at temperatures such as 55 °C, where the Caldo Boost still achieves an SCOP of 3.37 to 3.55 under EN 14825. An installer should check that your existing radiators heat each room well.
R290 is propane, a natural refrigerant with a very low GWP, which reduces the system's environmental impact. In the Caldo Boost the charge ranges from 0.95 to 1.45 kg depending on the model. Because it is flammable (class A3), installation must respect safety distances and be carried out by qualified technicians.
It delivers 159 L/h with the 8 kW model, 219 L/h with the 11 kW, 283 L/h with the 15 kW and 377 L/h with the 22 kW. Under 15/55 °C test conditions, DHW COP ranges from 3.51 to 4.71. Hot water is stored in a cylinder such as the Solitank or Enamel TSE-VS HP.
Yes. It is reversible and produces chilled water from 7 to 35 °C, with cooling capacity from 2.4–5.8 kW on the 8 kW model to 6.2–15.3 kW on the 22 kW, and an EER of 2.65 to 3.12. Cooling is delivered through fan coils or underfloor systems designed for cooling.
Our experts will get back to you shortly to analyse your needs.
For a faster quote, tell us: